Main Application | This furnace is designed for thick film products firing, such as Hybrid IC, chip-R, SMD components terminal, LTCC, Stainless steel heater, PV thin film cell and other similar products. |
Chamber structure | Use big chamber structure, use super light insulating material. |
The Effective Height above the belt | 50mm |
The layout | See table 1 |
Weight | About 2800Kg |
Overall dimension | 7720×1400×1350mm(L×W×H), (Exclude mounting feet and alarm lamp) |
Outlook | Outside panel use high temperature spraying coating and off-white color. RAL7035 |
Table 1 | |||
No. | Name | Length | Note |
A | Total length | 7720mm | |
B | Load and unload table | 600mm | Height from floor 770~820mm |
C | Furnace frame | 6520mm | |
D | Entrance Transition zone | 300mm | Include entrance curtain |
E | Insulation zone | 100mm | Insulation material insulation |
F | Heating zone | 4500 mm | 10 zones, length: 450mm each zone |
G | Insulation transition zone | 300mm | Insulation material insulation |
H | Cooling Zone | 1320mm | Stainless steel water jacket, include curtains, one temperature detective point in the water jacket. |
I | Furnace height | 1350mm | Exclude the height of stack |
J | Equipment operation panel position |
Rated Temperature Range | 850ºC |
Max. Temperature | 1000ºC |
Heating element | Heating board |
Heating power | 80KW |
Insulation Power of Empty furnace | ≤28kW |
Zone Number | 10 zones |
Temperature Control Point | 20 points |
Thermocouple | K type |
The temperature of furnace surface | <35ºC |
Discharge temperature at exit | <60ºC |
Control Accuracy | ±1ºC |
Temperature Uniformity | ±3ºC, (Flat-Temperature zone) |
Belt width | 600mm |
Belt material | Cr20Ni80 |
Max. load on the belt | 35kg/m2(exclude the belt weight) |
Drive system | big wrap angle friction drive |
Belt speed | 50~300mm/min, Typical work speed is 130~200 mm/min, stepless speed regulation control with frequency conversion. |
Driving system | Drive Control uses the servo system to control the speed by gear box. The speed is adjustable continually |
Conveyor device structure | Belt conveyor device: to drive the driving and driven wheel through chain and sprocket wheel, and then generate the friction force by driving wheel and the belt drive the belt running. There is a belt deviation guide device on the both sides at the entrance and exit |
Belt cleaning mode | Brush cleaning |
Ultrasonic cleaners |
Firing atmosphere | 5 compressed air, each flow can be adjusted, measuring range: 12~120L/min |
Exhaust System | Preheating zone have two exhaust stacks |
Table 2 | ||
No. | Name | Description |
A | Entrance curtains | Prevent outside air from entering the furnace |
B | Burn off gas inlet | Used for gas supplement of heating zone |
C | Exhaust gas inlet | The manual valve on Venturi exhaust tube can be used for adjusting gas flow |
D | Firing gas inlet | Used for control gas flow direction and prevent colloid pollution the products |
E | Exit curtains | Prevent outside air from entering the furnace |
The actual gas flow of each pipe can be displayed by flowmeters. |
Cooling structure | Stainless steel cooling water jacket, there is cooling fan at the exit table. |
Emergency Stop Button | two emergency stop buttons at the entrance and exit of the furnace, one for belt and one for power |
Alarm instructions | over temperature, thermocouple failure, low gas pressure,low water pressure, low water pressure, belt stop alarm, ignitor alarm and other audible and visual protection |
Temperature measuring | use K type thermocouple independent measuring and control on the temperature control point of each zone |
Temperature control | use of imported Intelligent temperature controller to control, with PID parameter auto tuning, high temperature upper limit alarm, thermocouple failure and other protective alarm functions |
Control mode | Solid state relay zero cross trigger mode |
Over Temperature Alarm | when over temperature occurred in some zones, over temperature alarm system in corresponding zones immediately send audible and visual alarm signal and meanwhile the heating of this zone is cut off, the buzzer sounds alarm. |
Computer Control System | Use DCS control system, |
Intelligent temperature controller control, industrial computer monitor | |
Friendly human-machine interface, industrial computer can carry out multiple programs saving | |
Real-time temperature and alarm record, data saving and printing. | |
It also can provide the temperature calibration function in the chamber for adjusting process requirement. |