Annealing Furnace for Solar Cell Glass Substrate with Computer Control

Product Details
Customization: Available
After-sales Service: 12 Months
Warranty: 12 Months
Manufacturer/Factory
Gold Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 9000
  • Annealing Furnace for Solar Cell Glass Substrate with Computer Control
  • Annealing Furnace for Solar Cell Glass Substrate with Computer Control
  • Annealing Furnace for Solar Cell Glass Substrate with Computer Control
  • Annealing Furnace for Solar Cell Glass Substrate with Computer Control
  • Annealing Furnace for Solar Cell Glass Substrate with Computer Control
  • Annealing Furnace for Solar Cell Glass Substrate with Computer Control
Find Similar Products

Basic Info.

Model NO.
HSK9100-3510
Type
Perovskite Heating Equipment
Certification
CE, ISO
Structure
Horizontal Type
Brand
Hengli
Maximum Temperature
350c
Glass Specification
1245*635*3mm
Number of Temperature Zones
18 Zones
Temperature Uniformity
+-5c
Transport Package
Wooden Box Iron Bracket
Specification
28200*2600*2000mm
Trademark
HENGLI
Origin
China
HS Code
8514390090
Production Capacity
700 Sets/Year

Product Description

HSK14005-1804Z Annealing Furnace
1,Typical application areas:
Typical application fields It is mainly used for the annealing heat treatment process of solar cell glass substrate under the condition of air atmosphere
2,Equipment specification and structure:
Annealing Furnace for Solar Cell Glass Substrate with Computer Control
 
Code Name Length Explain
A Total length 28200mm  
B Import/ export   platform 1500mm 1350±20mm above the ground,The length of import and export platforms are the same
 
C Furnace frame 25200mm  
D Import
transition section
900mm Including air curtain
E Import insulation transition 900mm Ceramic fiber material thermal insulation transition, including exhaust pipe
F Heating section 16200mm There are 18 temperature zones in total.The power is 14kw per zone and the length is 900mm per zone; The total design power is 252kw
G Free cooling zone 900mm No heating element, thermal insulation material
H Water cooling zone 4500mm Four sections water cold steel jacket (water cooling coil type), and the last section of steel jacket contains 350mm air curtain.
I Forced air cooling section 1800mm Forced air cooling with large air volume
K Equipment height 2000mm Excluding chimney, feet and indication light heigh
L Equipment operation panel layout location
Furnace structure Large furnace cavity and ultra light insulation material masonry structure are adopted
Effective height 50mm
Equipment weight About 27000kg
Overall dimension 28200×2600×2000mm(L×W×H),excluding foundation, chimney and indicator light
Appearance color The hanging plate adopts high-temperature plastic spraying, the color is camel gray computer color
Glass specification 1245×635×3mm;glass size deviation<±2mm,glass warpage degree≤3mm
Production cycle ≤60sec
Feeding mode Long side feed(1245mm)
Glass fragmentation rate <3‰
Equipment stability MTBF(Interval between equipment failures):≥720 hours/time
MTTR(Maintenance time of equipment failure):≤2hours/time
Uptime:≥98%
Schedule PM time:<1%
Unscheduled maintenance time:<1%
Special requirements The stainless steel tank ceiling device on the upper part of the furnace can effectively prevent the top insulation material from falling and improve the cleanliness of the furnace
3,Thermal system:
Rated temperature 300ºC
Maximum temperature 350ºC
Heating element Heating plates
Heating power 252kW
Empty furnace insulation power ≤90KW
Number of temperature zones 18 zones
Temperature control points 54  points(There are  left, middle and right temperature control points of each temperature zone, and the upper and lower proportional temperature control)
Thermocouple K type
Surface temperature rise <35ºC
Discharge temperature ≤60ºC(with belt speed 645mm/min)
Temperature control stability ±1ºC
Temperature uniformity ±5ºC(Constant temperature zone, cross section of the same belt)
4,Transmission system:
Belt width 1400mm
Belt model Wire diameter and threading diameter¢2.2*¢2.8,grid 8*16
Belt material Imported SUS316L
Maximum load 20Kg/m2(excluding the self weight of the belt)
Transmission mode Large wrap angle friction drive
Speed regulation range 300~1200mm/min,Typical belt speed of activation process 645mm/min
Driving system The transmission control adopts the frequency converter to drive the frequency conversion motor, which is controlled by the reducer, and the speed is continuously adjustable.
Conveyor structure The  belt conveyor is driven by sprocket and chain to drive the driving and driven wheels, and makes the mesh belt run through the friction between the driving wheel and the mesh belt. Mesh belt deviation correction devices are installed on both sides of the entrance and exit
Belt cleaning method Ultrasonic cleaner



5,Atmosphere system
Annealing Furnace for Solar Cell Glass Substrate with Computer Control
 
Atmosphere control system Including air pipe and exhaust system
Air pipes: the range of flowmeter is 48 ~ 480L / min; glass rotameter control
A Entrance air curtain Entrance air curtain (divided into three rows of air intake), and the range of each flowmeter is 48 ~ 480L / min
B Air inlet in heating parts Supplement of fresh air (intake air is divided into three rows), and the range of each flowmeter is 48 ~ 480L / min
C Rubber exhaust gas A set of waste gas collection pipeline and filtration system are set, which is controlled by micro pressure negative feedback, connected with the chimney and has the ability of mixing fresh air; Reduce the pipeline temperature; Pumping capacity ≤ 30m3 / min
D Air inlet in firing parts One pipe of intake air (divided into three rows). The range of each flow meter is 48 ~ 480L / min, which is distributed in the last water jacket of the water cooling section
E Exit air curtain The exit air curtain (divided into three rows of air intake), and the measuring range of each flowmeter is 48 ~ 480L / min
F Cooling exhaust In the air cooling area, the blower blows air, and the exhaust volume is about 50m3 / min
Each atmosphere flow meter displays the actual flow
6,Cooling system:
Cooling mode of water cooling area The surface of stainless steel cooling jacket is installed with water-cooled coil pipe
Cooling mode of  air cooling section Forced air cooling with large air volume
Cooling detection  1 point water temperature detection of cooling water jacket
Alarm indication Low water pressure alarm, overtemperature alarm, exhaust low negative pressure alarm
7,Safety protection:
Belt stop button Two belt stop button is set at the inlet and outlet end plates respectively. One for belt stop,one for power off.
Alarm indication Overtemperature, temperature deviation, frequency converter alarm, thermocouple broken, low gas pressure, low water pressure, discharge audible and visual alarm
8,Temperature control system:
Temperature measurement Each control and detection point is measured independently by K-type thermocouple
Control instrument It is controlled by imported intelligent regulation module.It has many alarm protection functions, such as PID parameter self-tuning, high temperature upper limit alarm, thermocouple failure indication and so on
Heating control The heating part is powered by multiple AC contactors in groups to reduce the instantaneous current impact of the equipment on the power grid
Control mode Solid state relay
Overtemperature treatment In case of overtemperature in a certain temperature zone, the temperature overtemperature alarm system of the temperature zone will immediately send out audible and visual alarm signals, cut off the heating in the corresponding temperature zone at the same time, and the buzzer will send out continuous alarm sound
Computer control system DCS (distributed control system) control system is adopted.
Lower computer, intelligent instrument control, upper computer monitoring
Friendly man-machine interface, multiple programs are stored, which is convenient for users to edit and call
Real time display of temperature and alarm status.The data can be stored and printed out.
Provide furnace temperature calibration function to better fit process requirements

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier