Customization: | Available |
---|---|
After-sales Service: | 12 Months |
Warranty: | 12 Months |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Main Application | This furnace is mainly used for high temperature firing of thick film heaters |
Code | Name | Length | Note | |
A | Total length | 22660mm | ||
B | Load table | 2500mm | Width 1100mm (only this section) | |
B" | Unload table | 600mm | ||
C | Furnace frame | 19560mm | ||
D | Drying entrance vestibule zone | 350mm | Include entrance curtain |
|
E | Drying section | 2000mm | 4 temperature zones, each temperature zone is 500mm long, with side lift structure. Upper and bottom heating in first zone with 6kw power each. Bottom heating in 2nd, 3rd and 4th temperature zones with 6kw power. 30kw power in total. -Including withdrawal system, to reach bottom IR lamps and radiation caps for cleaning and maintenance -Constant temperature along width of belt |
|
F | Drying exit vestibule zone | 350mm | Include entrance curtain | |
G | Vestibule zone between drying and firing section | 400mm | ||
H | Firing entrance vestibule zone | 350mm | Include entrance curtain | |
I | Entrance Insulation Zone | 150mm | Ceramic fiber insulation | |
J | Firing heating zone | 7590mm | 14 zones, the length of zone4,5,9,10,14: 330mm, the length of others: 660mm, The zones 1-8 are upper and bottom heating, and the rest of the zones are bottom heating only | |
K | Firing insulation transition section 1 | 1320mm | Ceramic fiber insulation | |
L | Firing insulation transition section 2 | 2740mm | ||
M | Water cooling zone | 2810mm | Water-cooled, including air curtain, air curtain length 350mm | |
N | Fan cooling zone | 1500mm | The fan blows directly, and the hot air collection cover is arranged above. The cooling fan is installed below the steel jacket. | |
L | Furnace Height | 1350mm | Belt height from the ground 914mm, ±25mm adjustable | |
M | Equipment operation panel position at the cooling section, on the left hand side when facing the loading table.The industrial computer system is installed separately outside the furnace body, with 20m connection cable reserved. |
|||
Chamber structure | Large furnace chamber with ultra-light insulation masonry structure | |||
The effective height above the belt | 80mm | |||
Weight | About 15500kg | |||
Overall dimension | 22660×1500×1350mm (L×W×H).(Exclude mounting feet and alarm lamp) | |||
Furnace appearance | Outside panel uses high temperature spraying coating and off-white color.Color is RAL9002 | |||
Special request |
The furnace chamber is lined with solid quartz rods | |||
Firing section chimney material using inconel 601 with 60mm diameter. | ||||
The industrial computer system is installed separately outside the furnace body, with 20m connection cable reserved |
Rated temperature | Drying section temperature can be set 100ºC to 200ºC, Firing section temperature can be set from 600ºC to 1000ºC. |
Max. temperature | 1050ºC |
Heating element | Infrared lamp for drying section, heating plate for firing section |
Heating power | 289kW (total power of drying section 30KW, total power of firing section 245KW, 28KW per temperature zone 1st, 2nd, 3rd, 6th, 7th ,8th. 14KW per temperature zone 4th, 5th, 11th, 12th, 13th, 7KW per temperature zone 9th, 10th, 14th ) |
Insulation Power | ≤98KW |
Heating zone | 18 zones |
Temperature Control Point | 46 points(Single-point temperature control for drying section, three-point temperature control for firing section) |
Thermocouple | K type in drying section. K type in Low temperature zone and N type in high temperature zone in firing section. |
Surface Temperature Heat up(not include the top of chamber) | <35ºC+room temperature |
Temperature Control Stability | ±1ºC |
Temperature Uniformity | ±2ºC ( Flat-Temperature zone of firing section) |
Belt width | 686mm |
Wire diameter and threading | B251014 |
Belt material | Cr20Ni80 2.4869 Balance type,wire diameter 2.2mm,thread 2.5mm, grid 10X14 |
Max Load on the Belt | 20Kg/m2(exclude the belt weight) |
Drive System | Big wrap angle friction drive |
Belt Speed | 75~800mm/min |
Drive system | Transmission control adopts servo motor, controlled by reducer, speed continuously adjustable |
Belt conveyor device | to drive the driving and driven wheel through chain and sprocket wheel, and then generate the friction force by driving wheel and the belt drive the belt running. There is a belt deviation guide device on the both sides at the entrance and exit. |
Belt cleaning method | Brush cleaning |
Atmosphere control system | Including air and exhaust system |
Air gas circuit: each flowmeter range of 48 to 480L/Min, the total inlet air with a high-precision filter to filter moisture. |
|||
A | Drying section entrance curtains | Import compressed air curtain, Prevent outside air from entering the chamber | |
B | Exhaust gas inlet of drying section | Inlet gas for assisted discharge, ventilated assisted discharge pipe are equipped with manual valves to adjust the gas flow size | |
C | Gas inlet in drying section | For fresh air replenishment in the heating zone of the drying section | |
D | Drying section exit curtains | Import compressed air curtain, Prevent outside air from entering the chamber | |
E | Firing section entrance curtains | Import compressed air curtain, Prevent outside air from entering the chamber | |
F | Burn off gas inlet of firing section | For fresh air replenishment in the warming area of the firing section | |
G | Exhaust gas inlet of firing section | Inlet air for assisted discharge with variable diameter ventilator, negative pressure monitoring, electronic micro differential pressure gauge (±125pa) | |
H | Firing gas inlet 1 | Control the airflow direction to prevent gum from contaminating the high temperature firing area | |
I | Firing gas inlet 2 | Control the airflow direction to prevent gum from contaminating the high temperature firing area | |
J | Exit curtains | prevent outside air from entering the furnace | |
Exhaust system | One exhaust stack for the drying section and one for the firing section |
Cooling structure | Stainless steel cooling jacket with bottom mounted cooling fan |
Cooling mode | A combination of mechanical fan direct blowing furnace tube cooling and water cooling |
Stop Belt Button | There is one stop button at each end plate of the entrance and exit, when pressed, the belt stops running. Please position buttons on left hand side when facing the load table (on long side not short side) |
Alarm instructions | Over-temperature, temperature deviation, servo alarm, thermocouple failure alarm, belt slip alarm, , heating elements current absent alarm, high pressure, low pressure alarm,cooling water failure alarm(low water pressure will engage the alarm, no water pressure will active the emergency stop) |
Emergency Stop Button | 1 emergency stop button for each inlet and outlet end plate (for cutting off power in case of emergency) plus manual shaking out device Please position buttons on left hand side when facing the load table (on long side not short side) |
Power-off Protection | add manual operating device |
Temperature measuring | Using K type thermocouple in drying section. use N type thermocouple independent measuring and control on the temperature control point of high temperature zones in firing section |
Control Meter | use of Intelligent temperature controller to control, with PID parameter auto tuning, high temperature upper limit alarm, thermocouple failure and other protective alarm functions |
Heating control | The heating part is powered by multiple AC contacts in groups to reduce the transient current impact of the equipment on the grid. |
Control Mode | Phase shifting power + solid state relay over zero trigger method |
Over Temperature | when over temperature occurred in some zones, over temperature alarm system in corresponding zones immediately send audible and visual alarm signal and meanwhile the heating of all zones are cut off, the buzzer sounds alarm |
Computer Control System | Use DCS control system, intelligent temperature controller control , industrial computer monitor, industrial computer(windows 10) can carry out multiple programs saving, real-time temperature and alarm record, data saving and printing and other functions. It also can provide the temperature calibration function in the chamber for adjusting process requirement |
If the furnace is not in working condition, it will be in holding condition. The holding temperature is manually down-transmitted and automatically down-transmitted at regular intervals with selected process parameters for temperature rise. |