686mm Belt Width Drying and Fring Belt Furnace for Thick Film Heater

Product Details
Customization: Available
After-sales Service: 12 Months
Warranty: 12 Months
Manufacturer/Factory
Gold Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 9000
  • 686mm Belt Width Drying and Fring Belt Furnace for Thick Film Heater
  • 686mm Belt Width Drying and Fring Belt Furnace for Thick Film Heater
  • 686mm Belt Width Drying and Fring Belt Furnace for Thick Film Heater
  • 686mm Belt Width Drying and Fring Belt Furnace for Thick Film Heater
  • 686mm Belt Width Drying and Fring Belt Furnace for Thick Film Heater
  • 686mm Belt Width Drying and Fring Belt Furnace for Thick Film Heater
Find Similar Products

Basic Info.

Model NO.
HSK6908-1811Z
Certification
CE, ISO
Structure
Horizontal Type
Brand
Hengli
Max. Temperature
1050 C
Heating Element
Infrared Lamp for Drying Section, Heating Plate Fo
Temperature Uniformity
+-2c
Belt Width
686mm
Transport Package
Wooden Box Iron Bracket
Specification
22660*1500*1350mm
Trademark
HENGLI
Origin
China
HS Code
8514390090
Production Capacity
800 Sets/Year

Product Description

686mm Belt Width Drying and Fring Belt Furnace for Thick Film HeaterHSK6908-1811Z Drying and firing Belt Furnace
1,Main Application:
Main Application This furnace is mainly used for high temperature firing of thick film heaters
2,Equipment specifications and structure:
686mm Belt Width Drying and Fring Belt Furnace for Thick Film Heater
Code Name Length Note
A Total length 22660mm  
B Load table 2500mm Width 1100mm (only this section)
  B" Unload table 600mm  
C Furnace frame 19560mm  
D Drying entrance vestibule zone 350mm Include entrance curtain
 
E Drying section 2000mm 4 temperature zones, each temperature zone is 500mm long, with side lift structure. Upper and bottom heating in first zone with 6kw power each. Bottom heating in 2nd, 3rd and 4th temperature zones with 6kw power. 30kw power in total.

-Including withdrawal system, to reach bottom IR lamps and radiation caps for cleaning and maintenance
-Constant temperature along width of belt
F Drying exit vestibule zone 350mm Include entrance curtain
G Vestibule zone between drying and firing section 400mm  
H Firing entrance vestibule zone 350mm Include entrance curtain
I Entrance Insulation Zone 150mm Ceramic fiber insulation
J Firing heating zone 7590mm 14 zones, the length of zone4,5,9,10,14: 330mm, the length of others: 660mm, The zones 1-8 are upper and bottom heating, and the rest of the zones are bottom heating only
K Firing insulation transition section 1 1320mm Ceramic fiber insulation
L Firing insulation transition section 2 2740mm  
M Water cooling zone 2810mm Water-cooled, including air curtain, air curtain length 350mm
N Fan cooling zone 1500mm The fan blows directly, and the hot air collection cover is arranged above. The cooling fan is installed below the steel jacket.
L Furnace Height 1350mm Belt height from the ground 914mm, ±25mm adjustable
M Equipment operation panel position at the cooling section, on the left hand side when facing the loading table.The industrial computer system is installed separately outside the furnace body, with 20m connection cable reserved.
686mm Belt Width Drying and Fring Belt Furnace for Thick Film Heater
Chamber structure Large furnace chamber with ultra-light insulation masonry structure
The effective height above the belt 80mm
Weight About 15500kg
Overall dimension 22660×1500×1350mm (L×W×H).(Exclude mounting feet and alarm lamp)
Furnace appearance Outside panel uses high temperature spraying coating and off-white color.Color is RAL9002

Special request
The furnace chamber is lined with solid quartz rods
Firing section chimney material using inconel 601 with 60mm diameter.
The industrial computer system is installed separately outside the furnace body, with 20m connection cable reserved
3,Thermal system:
Rated temperature Drying section temperature can be set 100ºC to 200ºC, Firing section temperature can be set from 600ºC to 1000ºC.
 
Max. temperature 1050ºC
Heating element Infrared lamp for drying section, heating plate for firing section
Heating power 289kW (total power of drying section 30KW, total power of firing section 245KW, 28KW per temperature zone 1st, 2nd, 3rd, 6th, 7th ,8th.
14KW per temperature zone 4th, 5th, 11th, 12th, 13th, 7KW per temperature zone 9th, 10th, 14th )
Insulation Power ≤98KW
Heating zone 18 zones
Temperature Control Point 46 points(Single-point temperature control for drying section, three-point temperature control for firing section)
Thermocouple K type in drying section. K type in Low temperature zone and N type in high temperature zone in firing section.
Surface Temperature Heat up(not include the top of chamber) <35ºC+room temperature
Temperature Control Stability ±1ºC
Temperature Uniformity  ±2ºC ( Flat-Temperature zone of firing section)
4,Drive system:
Belt width 686mm
Wire diameter and threading B251014
Belt material Cr20Ni80 2.4869 Balance type,wire diameter 2.2mm,thread 2.5mm, grid 10X14
Max Load on the Belt 20Kg/m2(exclude the belt weight)
Drive System  Big wrap angle friction drive
Belt Speed 75~800mm/min
Drive system Transmission control adopts servo motor, controlled by reducer, speed continuously adjustable
Belt conveyor device to drive the driving and driven wheel through chain and sprocket wheel, and then generate the friction force by driving wheel and the belt drive the belt running. There is a belt deviation guide device on the both sides at the entrance and exit.
Belt cleaning method Brush cleaning
5,Atmosphere control system:
686mm Belt Width Drying and Fring Belt Furnace for Thick Film Heater
Atmosphere control system Including air and exhaust system

Air gas circuit: each flowmeter range of 48 to 480L/Min, the total inlet air with a high-precision filter to filter moisture.

686mm Belt Width Drying and Fring Belt Furnace for Thick Film Heater







 
A Drying section entrance curtains Import compressed air curtain, Prevent outside air from entering the chamber
B Exhaust gas inlet of drying section Inlet gas for assisted discharge, ventilated assisted discharge pipe are equipped with manual valves to adjust the gas flow size
C Gas inlet in drying section For fresh air replenishment in the heating zone of the drying section
D Drying section exit curtains Import compressed air curtain, Prevent outside air from entering the chamber
E Firing section entrance curtains Import compressed air curtain, Prevent outside air from entering the chamber
F Burn off gas inlet of firing section For fresh air replenishment in the warming area of the firing section
G Exhaust gas inlet of firing section Inlet air for assisted discharge with variable diameter ventilator, negative pressure monitoring, electronic micro differential pressure gauge (±125pa)
H Firing gas inlet 1 Control the airflow direction to prevent gum from contaminating the high temperature firing area
I Firing gas inlet 2 Control the airflow direction to prevent gum from contaminating the high temperature firing area
J Exit curtains prevent outside air from entering the furnace
Exhaust system One exhaust stack for the drying section and one for the firing section

6,Cooling system:
Cooling structure Stainless steel cooling jacket with bottom mounted cooling fan
Cooling mode A combination of mechanical fan direct blowing furnace tube cooling and water cooling
7,Safety protect:
Stop Belt Button There is one stop button at each end plate of the entrance and exit, when pressed, the belt stops running.
Please position buttons on left hand side when facing the load table (on long side not short side)
686mm Belt Width Drying and Fring Belt Furnace for Thick Film Heater
Alarm instructions Over-temperature, temperature deviation, servo alarm, thermocouple failure alarm, belt slip alarm, , heating elements current absent alarm,  high pressure, low pressure alarm,cooling water failure alarm(low water pressure will engage the alarm, no water pressure will active the emergency stop)
Emergency Stop Button 1 emergency stop button for each inlet and outlet end plate (for cutting off power in case of emergency) plus manual shaking out device
Please position buttons on left hand side when facing the load table (on long side not short side)
Power-off Protection add manual operating device
8,Temperature control system:
Temperature measuring Using K type thermocouple in drying section. use N type thermocouple independent measuring and control on the temperature control point of high temperature zones in firing section
Control Meter use of Intelligent temperature controller to control, with PID parameter auto tuning, high temperature upper limit alarm, thermocouple failure and other protective alarm functions
Heating control The heating part is powered by multiple AC contacts in groups to reduce the transient current impact of the equipment on the grid.
Control Mode Phase shifting power + solid state relay over zero trigger method
Over Temperature when over temperature occurred in some zones, over temperature alarm system in corresponding zones immediately send audible and visual alarm signal and meanwhile the heating of all zones are cut off, the buzzer sounds alarm
Computer Control System Use DCS control system, intelligent temperature controller control , industrial computer monitor, industrial computer(windows 10) can carry out multiple programs saving, real-time temperature and alarm record, data saving and printing and other functions. It also can provide the temperature calibration function in the chamber for adjusting process requirement
If the furnace is not in working condition, it will be in holding condition. The holding temperature is manually down-transmitted and automatically down-transmitted at regular intervals with selected process parameters for temperature rise.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier