• Belt Muffle Furnace for Metal Brazing
  • Belt Muffle Furnace for Metal Brazing
  • Belt Muffle Furnace for Metal Brazing
  • Belt Muffle Furnace for Metal Brazing
  • Belt Muffle Furnace for Metal Brazing
  • Belt Muffle Furnace for Metal Brazing

Belt Muffle Furnace for Metal Brazing

After-sales Service: 12 Months
Warranty: 12 Months
Type: Brazing Furnace
Certification: CE, ISO
Structure: Horizontal Type
Brand: Hengli
Customization:
Gold Member Since 2012

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
HSA3510-0911ZNH
Max Temperature
1100c
Heating Element
Heating Wire Around Ceramic Bar
Zone Number
9 Zones
Temperature Control Stability
+-3c
Transport Package
Wooden Box Iron Bracket
Specification
13425*1200*1350mm
Trademark
HENGLI
Origin
China
HS Code
8514390090
Production Capacity
800 Sets/Year

Product Description

HSA3510-0911ZNH Firing Furnace
1,Main Application
Main Application This furnace is designed for high temperature firing of metal composite materials  in N2 and H2 atmosphere.
2,Specification and structure
Belt Muffle Furnace for Metal Brazing
Chamber structure Use big chamber and 8mm Inconel 601 muffle tube structure.
The Effective Height 100mm
Structure division See affix
Weight  About 3200Kg
Overall Dimension 13425×1200×1350mm(L×W×H),(Exclude mounting feet and alarm lamp)
Furnace Appearance Outside panel uses high temperature spraying coating and off-white color
3,Heating system
Rate Temperature  1050ºC
Max Temperature 1100ºC
Heating element Heating wire around ceramic bar
Heating power 72kW
Insulation Power of Empty Furnace: ≤25kW
Zone Number 9 zones
Temperature Control Point 9 point
Thermocouple K type, Watlow
Surface temperature rise <35ºC
Discharging Temperature ±1ºC
Temperature Control Stability ±3ºC(Flat-Temperature zone)
4,Drive System
Belt width 350mm
Belt Material SUS314
Max Load on the Belt 50Kg/m2(exclude the belt weight)
Drive Mode Big wrap angle friction drive.
Belt Speed 30~200mm/min, stepless speed regulation control with frequency conversion
Drive Control 20~150mm/min,typical speed: 60~70mm/min, stepless speed regulation control with frequency conversion
Drive System Drive Control uses the frequency converter drive frequency variable motor to control the speed by gear box. The speed is adjustable continually.
Belt cleaning mode Ultrasonic cleaning
5,Atmosphere Control System
Belt Muffle Furnace for Metal Brazing
Firing Atmosphere 7 pipes N2, the flowmeter range is 12~120L/Min; each pipe flow can be adjusted (See affix)
2 pipe H2, the flowmeter range is 5~50L/Min; the flow can be adjusted (See affix).
Oxygen content test There are 6 points to connect with oxygen analyzer that are Entrance transition part,Pre-heating part, high temp part, Heating preservation and cooling zone,cooling zone, and exit transition part. Detect the oxygen content  in real-time.
Automatic oxygen content test Oxygen analyzer online analysis, through the solenoid valve switching
Oxygen content index 10ppm+ oxygen content from gas source.
Exhaust System: Entrance and exit Vestibule jacket have 1 exhaust pipe separately.
6,Cooling system
Cooling structure  Water cooling jacket (SUS304)
Cooling mode Use gas cooling plus water cooling
Cooling detection 1 water temperature test point
Alarm instructions: Low water pressure alarm, over temperature alarm
7,Safety protection
Belt button One emergency stop buttons at the entrance and exit of the furnace ( for stopping the belt)
Alarm instructions Over temp, thermocouple failure, low gas pressure,  audible and visual protection.
power failure protection UPS protect the computer
Equipment safety heating rate ≤2ºC/min
8,Temperature Control System
Temperature Measuring: Use K type thermocouple independent measuring and control on the temperature control point of each zone.
Control instrument Use of intelligent temperature controller to control, with PID parameter auto tuning, high temperature upper limit alarm, thermocouple failure and other protective alarm functions.
Control Mode Solid State relay zero cross trigger mode.
Over Temperature Alarm: When over temperature occurred in some zones, over temperature alarm system in corresponding zones immediately send audible and visual alarm signal and meanwhile the heating of this zone is cut off, the buzzer sounds alarm
Computer Control System Use DCS control system
SIEMENS PLC control, upper industrial control computer monitoring
Industrial computer can carry out multiple programs saving
Real-time temperature and alarm record,data saving and printing.
The computer control system has a function of slope temperature rise, prolong the service life of the muffle tube
It also can provide the temperature calibration function in the chamber for adjusting process requirement.
Reserve the internet access  for remote reading data

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2012

Suppliers with verified business licenses

Manufacturer/Factory
Management System Certification
ISO 9001, ISO 9000