  • 355mm Belt Width Hot Air Reflow Oven
  • 355mm Belt Width Hot Air Reflow Oven
  • 355mm Belt Width Hot Air Reflow Oven
  • 355mm Belt Width Hot Air Reflow Oven
  • 355mm Belt Width Hot Air Reflow Oven
  • 355mm Belt Width Hot Air Reflow Oven
Find Similar Products

Basic Info.

Model NO.
HSF3605-0703
Type
SMT Equipment
Certification
CE, ISO
Structure
Horizontal Type
Brand
Hengli
Max Temperature
300c
Belt Width
355mm
Heating Mode
Heating Hot Air Circulation
Net Weight
3000kg
Cooling Mode
Fan Cooling
Transport Package
Wooden Box Iron Bracket
Specification
12595*1200*1450mm
Trademark
HENGLI
Origin
China
HS Code
8514390090
Production Capacity
800 Sets/Year

Product Description

  • Main Application:
This furnace is designed for reflow soldering of SMD parts , chip die attach and similar products. 
Technical Specification:
  1. Max Temperature: 300ºC,Temperature Range: RT~250ºC
    1. The Effective Above the Belt Clearance: ≤50mm
    2. Belt Width: 355mm
    3. Belt Material: SUS304
    4. Max Load on the Belt: 10Kg/m2(exclude the belt weight).
    5. Drive System: gears and belt drive
    6. Belt Speed: 87.5-700mm/min, Stepless speed regulation control with VFD.
    7. Heating Element:use nickel-chromium heating wire
    8. Heating Mode: heating hot air circulation
    9. Firing Atmosphere: air
    10. Exhaust System: one exhaust stack is located between the first and second zone, one exhaust stack is located between the second and third zone. And one exhaust stack is located at the seventh zone. There is a heating plate at exit of every stack. Please see the no. 3.2
    11. Cooling Mode: fan cooling.
    12. The Layout of Furnace Structure: Please see the no. 3.1  
    13. Temperature Control Stability: ±1ºC
    14. Chamber Temperature Uniformity: ±3ºC (Soaking Zone Temperature 200ºC)
    15. Temperature Zone: 7 zones
    16. Temperature Control Point: 7 points
    17. Thermocouple: K type
    18. Emergency Stop Button: There are two emergency stop buttons at the entrance and exit of the furnace.
    19. Alarm Protection: over temp, thermocouple failure, other audible and visual protective alarm.
    20. Heating Rate: ≤20ºC/min
    21. The Temperature of Furnace Surface:
    22. Outlet Temperature: <60ºC
    23. Heating Power: 72kW.
    24. The Insulation Power of the Empty Furnace: ≤25KW
    25. Power: Capacity >96KVA,    3   Phase   5  Line, Single Phase Voltage:  277  V Voltage between phases  480    V Frequency   60  HZ, the cable's color:Line wires: Brown, Orange, Yellow, Neutral: Grey or White, Ground: Green
    26. Weight: About 3000Kg.
    27. Overall Dimension: 12595×1200×1450mm (L×W×H).  
    28. Furnace Appearance: outside panel uses high temperature spraying coating and off-white color.
    29. General Description
      The furnace is divided into five major sections: furnace body, temperature control system, atmosphere control system, computer control system(reserved) and drive system.  
        
      3.1  Furnace Body Design
      Please see Table 1 and figure 1 for detailed layout of the furnace structure.
      355mm Belt Width Hot Air Reflow Oven
      Figure 1:Furnace Layout Drawing
       
      Table 1
      No.  Name Length Note
      A Total Length 12595mm  
      B Load Table 1000mm Distance from ground height 870 ~ 920 mm, adjustable.
      C Total length 10595mm  
      D Entrance Insulation Transition  Zone 400mm Including the 350mm air curtain
      E Heating Zone  8680mm 7 zones, the length of each zone is1240mm
      F Exit Insulation Transition  Zone 400mm Including the 350mm air curtain
      G Cooling Zone 1110mm No insulation material, mechanical fan blows the furnace tube directly.
      B" Unload Table 1000mm Distance from ground height 1,000~1,060 mm, adjustable.
      H Furnace Height 1450mm Exclude the supporting anchor and exhaust stack 
      G Computer operation position

      3.2  Atmosphere control system
      There are four air pipe: the flowmeter range for each gas is 12~120L/min. Please see Figure 2

      355mm Belt Width Hot Air Reflow Oven

                                      
      Figure 2 Atmosphere schematic diagram
      No. Name Note
      A Air curtain in Entrance Air atmosphere to prevent the air outside getting inside.
      B Venturi Exhaust Gas Inlet Venturi Exhaust gas inlet, can adjust the exhaust volume of two stacks.
      C Firing gas inlet Used for fresh air supplement.
      D Air curtain in Exit Air atmosphere to prevent the air outside getting inside.
      The actual gas flow of each pipe can be displayed by flowmeters


      3.3  The Design of Temperature Control System
    30. Temperature Measuring: use K type thermocouple independent measuring and control on the temperature control point of each zone.   
    31. Temperature Control: use of Intelligent temperature controller to control, with PID parameter auto tuning, high temperature upper limit alarm, thermocouple failure and other protective alarm functions.
    32. Heating Control System: after starting hot air circulation, the heating can be turned on. for the heating control, grouped supply the electricity by some alternating current contacts to reduce the instantaneous current impact to the electric fence caused by the equipment.
    33. Control Mode:Solid State relay zero cross trigger mode.
    34. Over Temperature Alarm: when over temperature occurred in some zones, over temperature alarm system in corresponding zones immediately send audible and visual alarm signal and meanwhile the heating of this zone is cut off, the buzzer sounds alarm.

    35. 3.3 Drive System Design
      3.3.1 Drive Control uses the VFD control the speed by gear box. The speed is adjustable continually.
      3.3.2Belt conveyor device: to drive the driving and driven wheel through chain and sprocket wheel, and then generate the friction force by driving wheel and the belt drive the belt running. There is a belt deviation guide device on the both sides at the entrance and exit.
      3.4  Industrial Computer system(reserved)
      This furnace is not equipped with industrial computer system at this time, the position for installing the computer system is reserved for updating in near future.
       

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier