Hsk Seies Drying and Firing Furnace for Stainless Steel Heater with Computer Control

Product Details
Customization: Available
After-sales Service: 12 Months
Warranty: 12 Months
Manufacturer/Factory
Gold Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 9000
  • Hsk Seies Drying and Firing Furnace for Stainless Steel Heater with Computer Control
  • Hsk Seies Drying and Firing Furnace for Stainless Steel Heater with Computer Control
  • Hsk Seies Drying and Firing Furnace for Stainless Steel Heater with Computer Control
  • Hsk Seies Drying and Firing Furnace for Stainless Steel Heater with Computer Control
  • Hsk Seies Drying and Firing Furnace for Stainless Steel Heater with Computer Control
  • Hsk Seies Drying and Firing Furnace for Stainless Steel Heater with Computer Control
Find Similar Products

Basic Info.

Model NO.
HSK Seies
Certification
CE, ISO
Structure
Horizontal Type
Brand
Hengli
Transport Package
Wooden Box Iron Bracket
Specification
12195*1400*1350mm
Trademark
HENGLI
Origin
China
HS Code
8514390090
Production Capacity
800set/Year

Product Description

   
     Hsk Seies Drying and Firing Furnace for Stainless Steel Heater with Computer ControlHSK6006-1211Z Belt Furnace
  • Main Application:
This furnace is designed for thick film products firing, such as Hybrid IC, chip-R, SMD components terminal, LTCC, Stainless steel heater, PV thin film cell and other similar products.  
Hsk Seies Drying and Firing Furnace for Stainless Steel Heater with Computer Control
,Technical Specification:
  1. Max Temperature: 1050ºC,Temperature Range: RT~900ºC,
    1. The Effective Height of the Product:  60mm
    2. Belt Width: 600mm.
    3. Belt Material: Cr20Ni80.
    4. Max Load on the Belt: 50Kg/m2(exclude the belt weight)
    5. Drive System: Big wrap angle friction drive.
    6. Belt Speed: 50~300mm/min, Stepless speed regulation control with frequency conversion, typical belt speed is about 150-180mm/min
    7. Heating Element:Use infrared quartz tube to heat from top and bottom. Firing furnace use FEC heater to heat from top and bottom heating mode
    8. Firing Atmosphere: Dry and clean Compressed air.
    9. Atmosphere Control: 13 compressed air inlet pipes
    10. Exhaust System: there are 2 exhaust stacks in the pre-Heating and firing section. 
    11. Cooling Mode: use insulation cooling+fan cooling and water cooling mixed cooling fans.
    12. The Layout of Furnace Structure: Please see the no. 3.1  
    13. Temperature Control Stability: ±1ºC.
    14. Chamber Temperature Uniformity: ±3ºC (test after keeping 2 hours at flat Temperature 850ºC),
    15. Temperature Zone:12 Zones.
    16. Temperature Control Point: 16 points( Zone 5-8 in the firing section use top bottom two points temperature control, others use single point control)
    17. Thermocouple: K type, made in China.
    18. Emergency Stop Button: There are two emergency stop buttons at the entrance and exit of the furnace.
    19. Alarm Protection: over temp, thermocouple failure, belt speed, motor over load, discharge, low gas pressure, other audible and visual protective alarm
    20. The Consumption of Compressed Air: 20~25m3/h.
    21. The Working Pressure of Compressed Air: 0.2-0.4MPa
    22. The Temperature of Furnace Surface:
    23. Heating Power:117Kw.
    24. The Insulation Power of the Empty Furnace: ≤40kW.
    25. Power: Capacity >153KVA, ,  3   Phase 5 Line, Single Phase Voltage:  220 V Voltage   between phases   380    V Frequency  60  HZ, the cable's color:    no requirement.
    26. Weight: About 4000Kg.
    27. Overall Dimension: 12195×1400×1350mm (L×W×H).
    28. Furnace Appearance: outside panel uses high temperature spraying coating and off-white color.

,General Description
The furnace is devided into four major sections: furnace body, Atmosphere control system, temperature control system and drive system.  
  
3.1 Furnace Body Design
Please see Table 1 and figure 1 for detailed layout of the furnace structure.

Hsk Seies Drying and Firing Furnace for Stainless Steel Heater with Computer Control

Feague 1:Furnace Layout Drawing
 
Name Length Note
Total Length 12195mm  
Load and Unload Table 600/1000mm Distance from ground height 770 ~ 820 mm, the length of load and unload table is the same.
Furnace frame 11410mm  
Entrance Vestibule Zone at Drying Section 350mm Include entrance curtain (multilayer stainless steel sheet).
Entrance Insulation Zone at Drying Section 65mm Ceramic fiber insulation
The Heating Zone at Drying Section 1500mm 3 zones, the length of each zone:500mm
Exit Insulation Zone 65mm Ceramic fibre material thermal transition
Transitional section 600mm Ceramic fibre material thermal transition
Terminal Insulation Transitional 150mm Insulation material
Heating Zone at Firing Section 4050mm 9 zones, the length of each zone is 450mm.
Insulation Zone at Firing Section 1500mm No heating elements, only insulation material
Forced Fan Cooling Zone at Firing Section 1065mm Mechanical cooling fan blow the furnace tube directly.
Water Cooling Zone at Firing Section 1250mm 1 segment water jacket(include exit curtain), water flow from bottom to the top.
Furnace Height 1350mm  


3.2  The Design of Temperature Control System
  1. Temperature Measuring: use K type thermocouple independent measuring and control on the temperature control point of each zone.   
  2. Temperature Control: use of Shimaden Intelligent temperature controller to control, with PID parameter auto tuning, high temperature upper limit alarm, thermocouple failure and other protective alarm functions.
  3. Heating Control System: for the heating control, grouped supply the electricity by 3 alternating current contactors to reduce the instantaneous current impact to the electric fence caused by the equipment.
  4. Control Mode:Solid State relay zero cross trigger mode.
  5. Over Temperature Alarm: when over temperature occurred in some zones, over temperature alarm system in corresponding zones immediately send audible and visual alarm signal and meanwhile the heating of this zone is cut off, the buzzer sounds alarm.

3.4 Drive System Design
3.4.1 Drive Control uses the frequency converter drive frequency variable motor to control the speed by gear box. The speed is adjustable continually.
3.4.2Belt conveyor device: to drive the driving and drived wheel through chain and sprocket wheel, and then generate the friction force by driving wheel and the belt drive the belt running. There is a belt deviation guide device on the both sides at the entrance and exit.

Others:
1.  Ultrasonic cleaning machine (cleaning mesh belt)
It can effectively clean the impurities and small particle on the belt to avoid product contamination.
2.  Discharge Alarm: photoelectric switch positioning.
The system will give out the alarm signal and audible indication when the parts get to the specified location.
3.  Computer Control System
Use DCS control system, intelligent temperature controller control (Shimaden), industrial computer monitor, industrial computer can carry out multiple programs saving, real-time temperature and alarm record, data saving and printing and other functions. It also can provide the temperature calibration function in the chamber for adjusting process requirement.
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier