Table 1 | |||
No. | Name | Length | Note |
A | Total Length | 22160mm | |
B | Load and Unload Table | 2000mm/600mm | Distance from ground height 840 ~ 890 mm, the length of load and unload table is the same. |
C | Furnace frame | 19560mm | |
D | Entrance Vestibule Zone | 350mm | Include entrance curtain (multilayer stainless steel sheet). |
E | Entrance Insulation Zone | 150mm | Ceramic fiber insulation |
F | The Heating Zone | 9600mm | 14 zones, the length of zone1~4: 900mm, power: 27kw, the length of others: 600mm, power: 12KW |
G | Free Cooling Zone |
3600mm | No heating element, thermal insulation material |
H | Exit Insulation Zone | 150mm | Ceramic fiber material insulation transition |
I | Water Cooling Zone 1 | 3000mm | Double layer stainless steel cooling water jacket structure, one point temperature detection |
J | Forced Fan Cooling Zone 2 | 2710mm | Force fan blow to the parts directly. |
K | Furnace Height | 1350mm | Exclude the mounting feet and exhaust stack height |
L | Equipment operation panel position |
Table 2 | ||
Code | Name | Explanation |
A | Entrance Curtains | Import gas curtain, Prevent outside air from entering the chamber |
B | Burn off left gas inlet | It is used to supplement of the fresh air in the heating zone, divided into two channels |
C |
Exhaust gas inlet left | gas inlet is used for exhaust, the exhaust chimney adopts the venturian pipe with variable diameter, the exhaust quantity is controlled by adjusting the pump air pressure, and the micro differential pressure gauge is equipped |
D |
Firing gas inlet left | It is used to control the flow direction of furnace to prevent the colloid pollution and firing of products in high temperature area |
E | Cooling gas inlet left 1 | It is used to control the flow direction of furnace to prevent the colloid pollution and firing of products in high temperature area |
F | Cooling gas inlet left 2 | |
G | Exit curtains | Prevent outside air from entering the furnace |
Exhaust system: There are 2 exhaust stacks in the preheating section (between zone 1 and 2, zone 2 and zone 3) |